| Parameter | Description |
| Active | If checked, the rule is enabled and will be processed |
| Backup type | To filter on a particular type of backup. Use this field to differentiate the monitoring of LOG and DATA by example |
| Max. Backup age | Defines the threshold for the maximum age of a backup |
| Severity | Defines the severity of the alert generated in the case of a too old backup (unless multi threshold syntax is used) |
| Error code | To set a particular backup error code to look for, use * to match any |
| Error severity | The severity of the generated alarm in case of backup errors |
| Auto clear | If set, the monitor will CLEAR any previous alarm if the conditions of those alarms are not true anymore |
| Alarm tag | You can define some text to use as a prefix of the alarm message generated by the current rule |
| Exclusive | If set to true and a backup error matches the Error field, this particular backup will not be processed by next rules |
| Alarm | Defines if an alarm has to be generated for the given rule |