-  %ID% :  replaces by the Alarm ID 
-  %GROUP% : replaces by the Group (Company) name 
-  %SID% : replaces by the System ID (SID) 
-  %INSTANCE% : replaces by the Redpeaks instance name 
-  %SEVERITY% : replaces by the the Alarm severity level 
-  %MESSAGE% : replaces by the message sent by the Alarm 
-  %MODULE% : replaces by the Alarm module 
-  %TO_CLEAR% : replaces by “true” or “false”  depending on if the Alarm is to be cleared or not 
-  %CLEARABLE% : replaces by “true” or “false”  depending on if the Alarm is a “can-be-cleared” type or not 
-  %COMPONENT% : replaces by the Alarm component (i.e. “disk”) 
-  %STACK% : replaces by the alarm stack type 
-  %ALARM_TAG% : replaces by the description of the alarm tag  
-  %CLEARED% : replaces by “CLEARED” if the Alarn has been already cleared or “” (none) if not 
-  %COUNT% : replaces by alarm counter 
-  %AGENT% : replaces by the Agent UUID (Redpeaks internal Agent unique identifier code) 
-  %SAMPLE_RATE% : replaces by the monitor sample rate as per execution schedule 
-  %RULE_NAME% : replaces by the name of the rule matched by the alarm, if any 
-  %RULE_DESCRIPTION% : replaces by the description of the rule matched by the alarm, if any 
-  %TIMESTAMP% : replaces by the formatted timestamp of the Alarm in local timezone 
-  %TIMESTAMP_UNIX% : replaces by the unformatted timestamp of the Alarm in UNIX epoch format (milliseconds since January 1st 1970) 
-  %TIMESTAMP_XXX% : replaces by the formatted timestamp of the Alarm using specified timezone (XXX):