| Parameter | Description |
| Active | Use this field to activate or deactivate a line of configuration. |
| Period | To limit the period of time in the past (minutes) to look for TRFC entries. Set 0 for checking since the last execution of this monitor. |
| Direction | The direction of the TRFC entries to check. |
| Destination | The destination of the transaction |
| Function/Prog | A filter to match only a given function or program |
| User | A filter to match only a given user or subset of users. |
| status | Defines the status of the TRFC entries to check. If set to SYSFAIL, it will only look for entries with SYSFAIL status. |
| Max entries | Defines the maximum number of entries matching the filters and status. |
| Max Sev. | Defines the severity of the alarm sent if maximum number of entries is reached. |
| Max entry age (hours) | Defines the maximum age of a TRFC entry matching the filters. Specified in hours. |
| Age Sev. | The severity of the too old entries alarm. |
| Auto clear | If checked, the alarm will be cleared as soon as the alarm condition is not met anymore. |
| Alarm tag | This field allows to add custom text within the alarm message. %MSG% variable will contain the actual generated message and can be used such as: “my_prefix %MSG% my_suffix”. By default, tag will be used as prefix. |
| Alarm | If checked, this line of surveillance will be used for alarm generation. |
| Metric | If checked, this line of surveillance will be used for metric generation. |
| Report | If checked, this line of surveillance will used for showing threshold and severity in the daily report |