Alerts

This monitor will collect the current alerts from HANA statistics engine.

Configuration hints

  • By default, this monitor will generate an alarm for each collected HANA alert matching the minimum severity settings, set to LOW by default.
  • Use the configuration table to create specific monitoring rules such as:
    • Exclude a particular host
    • Implement specific severity mapping
    • Manage specific alert id.
  • Any HANA alert which is not matching any filter of the table will trigger an alarm.
  • You can change that behavior by switching Unmatched alerts settings to REJECT.
  • In that case, only HANA alerts matching table filters will trigger an alarm.

Alarm severity mapping:

  • Use the alarm mapping table to modify severity mapping.
  • You can create a mapping for a specific HANA alert.

Default severity Mapping

HANA alert Generated severity
ERROR CRITICAL
HIGH MAJOR
MEDIUM MINOR
LOW WARNING
INFORMATIONAL INFORMATIONAL

Configuration

Atomic fields

Parameter Description
Auto clearIf checked the alarms will be cleared if the alert is not present anymore in the statistics engine
Send metadata When active, this will send collected alerts as metadata to Redpeaks Cockpit
Minimum severity The minimum severity of the alerts
Unmatched alerts How to handle unmatched alerts: PROCESS, REJECT

Configuration table table

Parameter Description
Active If checked, the rule is enabled and will be evaluated
Host Filters alerts associated to this specified host
Alert id Filters on a specific alert id
Min rating Filters alerts with a rating greater than or equal to this value
Required rating If not set to 'disabled', the alert must have exactly this rating to be processed
Auto clear If active, the generated alarms will be cleared automatically when the corresponding HANA alert will be cleared
Use index If active, the index of the HANA alert will be used in generated alarm id, making it unique
Alarm tag Sets an arbitrary tag for alarms generated by this rule. It can then be used for filtering in alarm rules

Rating mapping table

This table allows you to define custom mappings between HANA rating and Redpeaks severity per alert ID

Parameter Description
Active If checked, the mapping is active
Alert id Alert ID this mapping applies to
(IN) HANA Rating The HANA rating to match (e.g., HIGH, LOW, etc.)
(OUT) Redpeaks Severity The severity to assign when the above rating is matched.
If set to 'disabled', matching alerts are excluded

Notes

  • If both Min rating and Required rating are set to disabled, alerts matching the rule are excluded
  • If Required rating is active (i.e., not disabled), the alert must exactly match the specified rating to be processed
  • If (OUT) Redpeaks Severity is set to disabled, all alerts matching the specified (IN) HANA Rating will be excluded
  • To filter on a specific unique HANA alert ID, use the format ^X$, where X is the alert ID
    Example:
    Use ^7$ to match only alerts with ID 7