Add this page to your book
Remove this page from your book This monitor is dedicated to the monitoring of TRFC. It will watch for: - The number of TRFC with a given error status - The TRFC entries older than a given age.
You can customize the monitoring for a specific direction, destination, function/program or user.
Use the surveillance table to adjust the monitoring settings: Thresholds, severity, filters, etc… Unused threshold has to be set to 0.
| Parameter | Description |
|---|---|
| Active | Use this field to activate or deactivate a line of configuration. |
| Period | To limit the period of time in the past (minutes) to look for TRFC entries. Set 0 for checking since the last execution of this monitor. |
| Direction | The direction of the TRFC entries to check. |
| Destination | The destination of the transaction |
| Function/Prog | A filter to match only a given function or program |
| User | A filter to match only a given user or subset of users. |
| status | Defines the status of the TRFC entries to check. If set to SYSFAIL, it will only look for entries with SYSFAIL status. |
| Max entries | Defines the maximum number of entries matching the filters and status. |
| Max Sev. | Defines the severity of the alarm sent if maximum number of entries is reached. |
| Max entry age (hours) | Defines the maximum age of a TRFC entry matching the filters. Specified in hours. |
| Age Sev. | The severity of the too old entries alarm. |
| Auto clear | If checked, the alarm will be cleared as soon as the alarm condition is not met anymore. |
| Alarm tag | This field allows to add custom text within the alarm message. %MSG% variable will contain the actual generated message and can be used such as: “my_prefix %MSG% my_suffix”. By default, tag will be used as prefix. |
| Alarm | If checked, this line of surveillance will be used for alarm generation. |
| Metric | If checked, this line of surveillance will be used for metric generation. |
| Report | If checked, this line of surveillance will used for showing threshold and severity in the daily report |
| Active | Period | Direction | Destination | Function/Prog | User | status | Max entries | Max Sev. | Max entry age (hours) | Age Sev. | Auto clear | Alarm tag | Alarm | Metric | Report |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| true | 15 | OUTBOUND | * | * | * | SYSFAIL | 10 | MAJOR | WARNING | true | true | false | false | false |
Effect : Sends a MAJOR alarm if there are 10 or more OUTBOUND TRFC entries with SYSFAIL status in the last 15 minutes
| Active | Period | Direction | Destination | Function/Prog | User | status | Max entries | Max Sev. | Max entry age (hours) | Age Sev. | Auto clear | Alarm tag | Alarm | Metric | Report |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| true | 15 | INBOUND | * | * | * | IN_PROCESS | 1 | MAJOR | WARNING | true | true | false | false | false |
Effect : Sends a WARNING alarm if any INBOUND TRFC entry not beeing in error state is older than one hour in the last 15 minutes
| metricId | metricUnit | metricTarget | metricDescription |
|---|---|---|---|
| TRFC_IN_ENTRIES | Entries | [STATUS][INSTANCE][FUNC][USER] | The number of INBOUND TRFC entries matching the filter |
| TRFC_OUT_ENTRIES | Entries | [STATUS][INSTANCE][FUNC][USER] | The number of OUTBOUND TRFC entries matching the filter |