products:promonitor:6.8_old:userguide:configuration:systemsconnectors:common

Common connectors settings

Describes common parameters and behaviors of connectors.

Custom timeout

Context

  • A Connector is tested every two minutes when it is active
  • Alarms will be generated when the connection fails

Max invalid time

  • To avoid false alarms caused by transient problems, the Max invalid time parameters defines the maximum time a connector can fail before sending an alarm.
  • Example for a timeout set to 5 min:
    • 12:00 → Check OK
    • 12:02 → Check Failed
    • 12:04 → Check OK
    • No alarm is sent: The connector failed for less than 5 minutes

Max response time

  • Another parameter which plays a role in the connection check is Max response time
  • If the system doesn't respond to a connection attempt within the allocated max response time, the connection will be considered as failed.
  • This parameter helps to avoid false alarms for slow systems which sometimes take longer to respond.

Override default settings

  • Max invalid time and Max response time are global settings defined in the admin configuration
  • However, those settings can be overriden in the connector settings
  • Just enable the custom timeout check box to customize those timeouts